This page will display a series of cases which will be sequentially put up. Your comments and responses will be appreciated.

Case Courtesy : Le Visage, Mumbai, INDIA System Followed : Automated Endodontics
Preoperative Radiograph File Length measurement - Broken Lentulo in Distal
Broken spiral jumped into mesial Post op Radiograph
History : A 22 year old female patient reported with severe pain in the lower first molar which had been treated almost a decade ago. During biomech a broken lentulo spiral was seen lodged in the distal canal. During removal it jumped into the mesial from where it was retrieved. Subsequently a complete obturation was carried out.
Comments :
Click here to see a video of the washed field technique


 